Installation and Operation Guide
ED-DT318B
Drive Train Systems with Traction Control, Inverter/Controller, and Motor with 2 Speed Transmission
BC353060341319en-000101
Revision D
© Danfoss | November 2020 | 174
Status Signal
Time period
before
reacting
Typical Vehicle Controller Unit (VCU) Expected
Action
Recommended Service Action
MCU Rotor Temperature
Section
Long
MCU Rotor Over Temp signal is set at 130° C
Amber over temp light if over 136° C
Red over temp light if over 146° C
Note: Torque production is limited beginning at 130°
C and reaches 0Nm at 150° C
X
MCU Max Source Current
Section
X
Nothing – this value is set as the result of changes in
the Max Source Current (
Section
.
Note: The max value of this signal is defined by the
MCU.
X
MCU Max Sink Current
Section
X
Nothing – this value is set as the result of changes in
the Max Sink Current (
Section
.
Note: The max value of this signal is defined by the
MCU.
X
NOTICE
If MCU
Over Phase Advance
is persistently detected over time, contact Danfoss Power Solutions for a motor specific Danfoss Power
Solutions file (
Section 8
). Danfoss Power Solutions will require the serial number of the motor and a copy of the current QSC to process
this request.
The QSC is for the specific motor. If the motor is replaced, revert to the original QSC or load the QSC for the replacement motor