If the fastener securing the wire harness to the transmission (at topmost transmission mounting point in
) is disrupted and used for a mounting bracket attachment point, it is the customer’s responsibility to fasten
the wire harness to the transmission in the same position as the original wire harness mounting scheme. The
wire harness must be secured to alleviate any potential of rubbing on transmission housing and respective
components, if this requirement is disregarded damage to harness may occur.
Each mounting bracket (4X) should incorporate an adequately sized vibration isolator.
The minimum distance from the isolator to the centerline of the transmission output shaft is 200mm; refer to
for recommended location of isolators. The Danfoss Power Solutions recommended isolator is
Hutchison 22003, 11, 12 or 13 and should be sized based on customer requirements. The customer should
contact Hutchinson, Inc. directly at 1-508-417-7000 to discuss specific vehicle application requirements.
WARNING
The motor housing is not a structural member and is not intended to bear structural
loads.
WARNING
Exercise care when mounting the motor and transmission to ensure that moving
parts are not constrained and proper clearances are observed. All drive mechanisms
mounted to the transmission shaft must be properly secured.
WARNING
Loads on the motor shaft induced by the coupling system can result in premature
motor failure. Users of the motor MUST ensure the motor shaft is not improperly
loaded.
WARNING
A separate ground wire must connect the motor case to the controller housing. High
Voltage lines (positive or negative) must not be tied to the chassis, or the motor and
controller/inverter cases. Please see
Section 3.2
for more information on grounding
requirements.
2.3.3
Overall Clearance Recommendation
•
At least 19mm required clearance for powertrain package with surrounding structure
•
Transmission shall be angled between 3 and 9.75 Degrees downward from level ground.
Figure 2.4: Mounting angle limits