Installation and Operation Guide
ED-DT318B
Drive Train Systems with Traction Control, Inverter/Controller, and Motor with 2 Speed Transmission
BC353060341319en-000101
Revision D
© Danfoss | November 2020 | 62
Classified as Business
Note 3: When the transmission is in low gear, motor speed should never be allowed to exceed
6000 rpm.
Note 4: When the transmission is in high gear, motor speed should never be allowed to exceed
4800 rpm.
Note 5: The transmission will achieve reverse operation in High Gear if and only if it encounters a
shift failure from High to Low gear.
7.2.1.7
Speed Limit
dbc ref:
TCUCmd1_SpeedLimit
lsb:
33
msb:
48
Offset:
0
Scale Factor: 1
Min Value:
0
Max Value:
4800
Units:
rpm
Description: The maximum speed, in rpm, to be delivered by the transmission to the driveshaft.
When the
Transmission Mode
is Neutral, this value will be treated as if it is 0.
When the
Transmission Mode
is Reverse, Forward Low, Forward High or Forward Automatic: this
is the maximum speed the transmission will supply to the driveshaft. The actual speed will be
controlled by the
Drive Torque
as long as it does not result in speeds in excess of the
Speed
value
When the
Transmission Mode
is either Reverse or Forward Low, values that exceed
the lessor of 6000 rpm or the maximum speed allowed by the MCU
3.529
will be treated as if they were that value.
When
Transmission Mode
is either Forward High or Forward Automatic, values that exceed
4800 rpm will be treated as if they were that value.
7.2.1.8
Requested Torque
dbc ref:
TCUCmd1_RequestedTorque
lsb:
1
msb:
32
Offset:
0 (Signed int)
Scale Factor: 0.1
Min Value:
-6425.6
Max Value:
6425.5
Units:
Nm
Description: The amount of torque the VCU is requesting the system deliver to the driveshaft.