Installation and Operation Guide
ED-DT318B
Drive Train Systems with Traction Control, Inverter/Controller, and Motor with 2 Speed Transmission
BC353060341319en-000101
Revision D
© Danfoss | November 2020 | 22
Classified as Business
High operating temperatures may require more frequent oil change.
2.4.1.5
Maintenance Interval
The recommended transmission oil change interval is the lesser of 300,000 km or 3 years at vocational bus
application
2.4.1.6
Transmission Operating Angles
The transmission operating angle should not exceed 20° from the horizontal (18% road slope at transmission
installation angle of 9.8°)
2.4.1.7
Lubrication checking procedure
Oil Level
Before checking the oil level or refilling, ensure vehicle is on level ground. Make sure that the oil is level with the
filler opening.
Draining Oil
Drain transmission while oil is warm. To drain oil remove the drain plug at the bottom of the case, or Remove
strainer from the intermediate case (
). Clean the drain plug with kerosene before refitting.
Before draining the oil, ensure that oil is warm and the vehicle is on level ground.
To drain the oil, remove the drain plug from the left-hand side bottom of the intermediate case.
Figure 2.7: Transmission lubricant drain
Refilling transmission
Before refilling the transmission:
•
Remove and clean the oil strainer. Clean the strainer in kerosene (paraffin) or suitable solvent and dry
thoroughly. Renew the washer and the O-ring if necessary. When refitting, tighten to the torque (40 to
47 Nm).