Installation and Operation Guide
ED-DT318B
Drive Train Systems with Traction Control, Inverter/Controller, and Motor with 2 Speed Transmission
BC353060341319en-000101
Revision D
© Danfoss | November 2020 | 148
Classified as Business
One feature specific to the Event Log is the revolution counter event. This feature logs an event into the Event
Log representing that a user configurable number of motor revolutions have occurred. This can be thought of as
a "mileage counter" when the number of revolutions equates to a distance.
Figure 8.21: Event Dialog Box
Table 8.13: Possible Entries in Event Log
Entries
Description
*** Start of data ***
This marks the beginning of the oldest data.
****XX blank events****
Means that the Event Log is not yet full. Once it is full, then the
oldest event is written over by the newest event, and there are no
more blanks.
Processor start up
This marks that the controller went through a power up or a reset.
The operating time is zero at this point.
Содержание ED-DT318B
Страница 185: ......