Installation and Operation Guide
ED-DT318B
Drive Train Systems with Traction Control, Inverter/Controller, and Motor with 2 Speed Transmission
BC353060341319en-000101
Revision D
© Danfoss | November 2020 | 103
Classified as Business
7.3.3.21
MCU Rotor Over Temperature
dbc ref:
TCUStat3_MCURotorOverTemperature
lsb:
44
msb:
44
Offset:
0
Scale Factor: 1
Min Value:
0
Max Value:
1
Units:
Boolean
Description: True
The motor’s rotor temperature exceeds normal operating limits.
False
The motor’s rotor temperature is within normal operating limits.
When this condition occurs, the MCU attempts to lower the maximum torque the system can
produce until it reaches a point at which the temperature no longer exceeds the limit. The MCU
will then produce as much torque as it can while keeping the temperature at or just below the
limit.
7.3.3.22
MCU Rotor Over Temperature History
dbc ref:
TCUStat3_MCURotorOverTemperatureHistory
lsb:
43
msb:
43
Offset:
0
Scale Factor: 1
Min Value:
0
Max Value:
1
Units:
Boolean
Description: True
MCU
Rotor Over Temperature
has been set to True at some point since the last time
MCU power was cycled.
False
MCU
Rotor Over Temperature
has not been set to True at any point since the last time
MCU power was cycled.
7.3.3.23
MCU Under Voltage Warning
dbc ref:
TCUStat3_MCUUnderVoltageWarning
lsb:
42
msb:
42
Offset:
0
Scale Factor: 1
Min Value:
0