7.3.7
TCU Status Message 7
ID:
PDU1: 1CEErrss
16
PDU2: 1CFFgess
16
11 bit: xrr1
16
From:
TCU
To:
VCU
Msg Rate:
50ms
Note:
The TCU will transmit this message immediately following the transmission of the
Status
Message 6
. The VCU will detect whether or not the message is received and will react as
appropriate.
64
63
62
61
60
59
58
57
MCU Stall Safety Percentage
56
55
54
53
52
51
50
49
TCU Lubricant Temperature
48
47
46
45
44
43
42
41
MCU Inverter Temperature
40
39
38
37
36
35
34
33
MCU Stator Temperature
32
31
30
29
28
27
26
25
MCU Rotor Temperature
24
23
22
21
20
19
18
17
MCU Max Source Current
16
15
14
13
12
11
10
9
MCU Max Sink Current
8
7
6
5
4
3
2
1
7.3.7.1
MCU Stall Safety Percentage
dbc ref:
TCUStat7_StallSafetyPercentage
lsb:
57
msb:
64
Offset:
0