Installation and Operation Guide
ED-DT318B
Drive Train Systems with Traction Control, Inverter/Controller, and Motor with 2 Speed Transmission
BC353060341319en-000101
Revision D
© Danfoss | November 2020 | 105
Classified as Business
7.3.3.26
MCU Over Phase Advance History
dbc ref:
TCUStat3_MCUOverPhaseAdvanceHistory
lsb:
39
msb:
39
Offset:
0
Scale Factor: 1
Min Value:
0
Max Value:
1
Units:
Boolean
Description: True
MCU
Over Phase Advance
has been set to True at some point since the last time MCU
power was cycled.
False
MCU
Over Phase Advance
has not been set to True at any point since the last time MCU
power was cycled.
7.3.3.27
MCU Over Bus Current
dbc ref:
TCUStat3_MCUOverBusCurrent
lsb:
38
msb:
38
Offset:
0
Scale Factor: 1
Min Value:
0
Max Value:
1
Units:
Boolean
Description: True
The DC bus currents are exceeding their normal operating parameters.
False
The DC bus currents are within their normal operating parameters.
7.3.3.28
MCU Over Bus Current History
dbc ref:
TCUStat3_MCUOverBusCurrentHistory
lsb:
37
msb:
37
Offset:
0
Scale Factor: 1
Min Value:
0
Max Value:
1
Units:
Boolean
Description: True
MCU
Over Bus Current
has been set to True at some point since the last time MCU
power was cycled.