Installation and Operation Guide
ED-DT318B
Drive Train Systems with Traction Control, Inverter/Controller, and Motor with 2 Speed Transmission
BC353060341319en-000101
Revision D
© Danfoss | November 2020 | 117
Classified as Business
lsb:
1
msb:
16
Offset:
0
Scale Factor: 1
Min Value:
0
Max Value:
32128
Units:
A
Description: The absolute value of the peak currents passing through the motor’s phase leads (the large
cables between the inverter and the motor). The value is equal to the largest Leg Current value
detected between successive MCU status report messages. It is representative of the currents
driving the motor when it is motoring, or being produced by the motor when it is generating.
Содержание ED-DT318B