7.3.7.4
MCU Stator Temperature
dbc ref:
TCUStat7_MCUStatorTemperature
lsb:
33
msb:
40
Offset:
-40
Scale Factor: 1
Min Value:
-40
Max Value:
210
Units:
˚C
Description: The temperature of the motor stator.
Note: The MCU will limit motor torque to keep this temperature within acceptable limits.
7.3.7.5
MCU Rotor Temperature
dbc ref:
TCUStat7_MCURotorTemperature
lsb:
25
msb:
32
Offset:
-40
Scale Factor: 1
Min Value:
-40
Max Value:
210
Units:
˚C
Description: The temperature of the motor rotor.
Note: The MCU will limit motor torque to keep this temperature within acceptable limits
7.3.7.6
MCU Max Source Current
dbc ref:
TCUStat7_MCUMaxSourceCurrent
lsb:
17
msb:
24
Offset:
0
Scale Factor: 5
Min Value:
0
Max Value:
1275
Units:
Amps
Description: The maximum current the MCU is allowed to source to the battery when in regen.