Installation and Operation Guide
ED-DT318B
Drive Train Systems with Traction Control, Inverter/Controller, and Motor with 2 Speed Transmission
BC353060341319en-000101
Revision D
© Danfoss | November 2020 | 116
Classified as Business
Scale Factor: 1
Min Value:
0
Max Value:
32768
Units:
rpm/s
Description: The maximum allowed rate of controlled acceleration/deceleration.
If this value is 0, the MCU will use its configured default value.
If the VCU commands a value greater than 50, the MCU will use that value instead of the
configured default.
If the VCU commands a value greater than 50 and then commands a value less than 50, the
greater value will remain in effect and will be reflected in this value.
Note: this value is the acceleration limit seen at the transmission output. Therefore the limit
reported by the MCU will be divided by 3.529 when in low gear or reverse operation in low gear.
7.3.6.2
MCU Voltage
dbc ref:
TCUStat6_MCUVoltage
lsb:
33
msb:
48
Offset:
0 (signed int)
Scale Factor: 0.1
Min Value:
-3212.8
Max Value:
3212.8
Units:
VDC
Description: The DC bus voltage available at the DC input terminals of the MCU.
7.3.6.3
MCU Current
dbc ref:
TCUStat6_MCUCurrent
lsb:
17
msb:
32
Offset:
0 (signed int)
Scale Factor: 0.1
Min Value:
-3212.8
Max Value:
3212.8
Units:
A
Description: The DC bus current being consumed (motoring) or produced (regeneration) by the MCU. Positive
values indicate motoring, while negative values indicate regeneration operation.