Installation and Operation Guide
ED-DT318B
Drive Train Systems with Traction Control, Inverter/Controller, and Motor with 2 Speed Transmission
BC353060341319en-000101
Revision D
© Danfoss | November 2020 | 81
Classified as Business
Min Value:
0
Max Value:
1
Units:
Boolean
Description: True
The MCU is reporting a Watchdog timeout to the TCU.
False
The MCU is not reporting a Watchdog timeout to the TCU.
7.3.2.18
TCU Command Message 1 Error
dbc ref:
TCUStat2_TCUCommandMessage_1_Error
lsb:
43
msb:
43
Offset:
0
Scale Factor: 1
Min Value:
0
Max Value:
1
Units:
Boolean
Description: True
The TCU has detected 1 of 2 indications that a message has been missed:
•
The TCU has received 1 or more
TCU Command Message 1
messages from the VCU
in which the
VCU
Watchdog Counter 1
is out of sequence.
•
The TCU has not received a
TCU Command Message 1
messages from the VCU in
150% of the normally allotted time.
False
The MCU has received the last 3 commands from the VCU within 150% of the normally
allotted time and in each of the messages the
VCU
Watchdog Counter 1
is in sequence.
Note: At startup, this bit will be True until the MCU receives 3 commands from the VCU within
150% of the normally allotted time and in each of the messages the
Watchdog Counter
is in sequence.
7.3.2.19
TCU Command Message 1 Watchdog Timeout
dbc ref:
TCUStat2_TCUCommandMessage_1_WatchdogTimeout
lsb:
42
msb:
42
Offset:
0
Scale Factor: 1
Min Value:
0
Max Value:
1
Units:
Boolean
Description: True
The MCU has not received a
TCU Command Message 1
message within the last second.
False
The MCU has received a
TCU Command Message 1
message within the last second.