Installation and Operation Guide
ED-DT318B
Drive Train Systems with Traction Control, Inverter/Controller, and Motor with 2 Speed Transmission
BC353060341319en-000101
Revision D
© Danfoss | November 2020 | 110
Classified as Business
Scale Factor: 0.1
Min Value:
0
Max Value:
6425.6
Units:
Nm
Description: This is the maximum drive torque the system is capable of delivering to the driveshaft under
current operating conditions.
This value is derived from the MCU’s Max Drive Torque Allowed and is corrected for the Low/High
gear ratio.
This value will also be derated by 10% for each increase of 0.5˚C above 120˚C in the temperature
of the transmission lubricant temperature.
7.3.4.2
Max Regen Torque Allowed
dbc ref:
TCUStat4_MaxRegenTorqueAllowed
lsb:
33
msb:
48
Offset:
0
Scale Factor: 0.1
Min Value:
0
Max Value:
6425.6
Units:
Nm
Description: This is the maximum regen torque the system is capable of delivering to the driveshaft under
current operating conditions.
This value is derived from the MCU’s Max Regen Torque Allowed and is corrected for the
Low/High gear ratio.
This value will also be derated by 10% for each increase of 0.5˚C above 120˚C in the temperature
of the transmission lubricant temperature.
7.3.4.3
VCU Torque Requested
dbc ref:
TCUStat4_VCUTorqueRequested
lsb:
1
msb:
32
Offset:
0 (signed int)
Scale Factor: 0.1
Min Value:
-6425.6
Max Value:
6425.5
Units:
Nm
Description: The amount of torque the TCU is requesting the system to deliver to the driveshaft. This is the
amount of torque the VCU requested in TCU Command Message 1 after it has been limited to the
Max Drive and Max Regen Torque Allowed.