BE1-CDS220 Command
Cross-Reference
B-3
ASCII Command
Function
HMI Screen
RA-MAJ[=0]
Report/Reset major alarm information.
1.2
RA-MIN[=0]
Report/Reset minor alarm information.
1.2
RA-REL[=0]
Report/Reset relay alarm information.
1.2
RA-SER[=0]
Report relay alarm sequence of events information.
N/A
RB
Read breaker status.
1.4.5, 4.3
RB-DUTY[<phase>[=%duty>]]
Read/Set breaker contact duty log.
4.3.1
RB-OPCNTR[=<#operations>]
Read/Set breaker operation counter.
4.3.1
RD
Report all demand data.
4.4
RD-LOG<n>
Report load profile data.
N/A
RD-PI[<p>[=0]]
Read/Reset peak demand current.
4.4.3.1
∗
RD-TI[<p>]
Report today’s demand current.
4.4.1.1
∗
RD-YI[<p>]
Report yesterday’s demand current.
4.4.2.1
∗
RF[-n/NEW][=0/TRIG]
Read/Reset fault report data.
N/A
RG
Report general information.
N/A
RG-101STAT
Report general information, 101 status.
2.2
RG-43STAT
Report general information, 43 status.
2.1.x,1.4.3
RG-ADDR[x]
Report/Set COM1/COM2 Address for Polled
Communications.
6.1.x
RG-BREAKER
Report general information, breaker status.
1.4.5
RG-DATE[=<M/D/Y>]
Read/Set date.
1.4.6
RG-GRPACTIVE
Report active group.
1.4.4
RG-GRPCNTRL
Report group logic override control status.
2.3.x
RG-INPUT
Report input status.
1.4.1
RG-LOGIC
Report active logic.
5.0
RG-OUTCNTROL
Report output control status.
2.4, 1.4.2
RG-OUTSTAT
Report output status.
1.4.2
RG-STAT
Report relay status.
N/A
RG-TARG
Report/Reset target status.
1.1
RG-TIME[=hr:mn:sc]
Report/Set time.
1.4.6
RG-VER
Read program version, model number, style
number, and serial number.
4.6
RL
Read logic variables.
N/A
RO-nA/B[#].CFG/DAT/HDR
Read oscillographic COMTRADE .DAT/.CFG/.HDR
fault report.
N/A
RS
Read sequence of events directory
N/A
RS[-n/Fn/ALM/IO/LGC/NEW] [=0]
Read/Reset sequence of events record data
N/A
RT
Read Transformer Duty Status
4.5.1
RT-DUTY
Read/Set transformer through-fault duty log
4.5.1
RT-TFCNTR[=0]
Read/Set transformer through fault counter
4.5.1
∗
Multiple screens required.
Table B-5. Setting Command
ASCII Command
Function
HMI Screen
S
Read all relay setting parameters.
N/A
Содержание BE1-CDS220
Страница 2: ......
Страница 10: ...viii Introduction BE1 CDS220 This page intentionally left blank...
Страница 36: ...ii Quick Start BE1 CDS220 This page intentionally left blank...
Страница 48: ...ii Input And Output Functions BE1 CDS220 This page intentionally left blank...
Страница 66: ...iv Protection and Control BE1 CDS220 This page intentionally left blank...
Страница 112: ...ii Metering BE1 CDS220 This page intentionally left blank...
Страница 116: ...5 4 Metering BE1 CDS220 This page intentionally left blank...
Страница 166: ...ii BESTlogic Programmable Logic BE1 CDS220 This page intentionally left blank...
Страница 176: ...7 10 BESTlogic Programmable Logic BE1 CDS220 This page intentionally left blank...
Страница 234: ...8 56 Application BE1 CDS220 This page intentionally left blank...
Страница 236: ...ii Security BE1 CDS220 This page intentionally left blank...
Страница 240: ...9 4 Security BE1 CDS220 This page intentionally left blank...
Страница 242: ...ii Human Machine Interface BE1 CDS220 This page intentionally left blank...
Страница 256: ...10 14 Human Machine Interface BE1 CDS220 This page intentionally left blank...
Страница 258: ...ii ASCII Command Interface BE1 CDS220 This page intentionally left blank...
Страница 289: ...BE1 CDS220 Installation 12 7 Figure 12 8 MX Case Horizontal Panel Mount Front View Overall Dimensions...
Страница 422: ...14 32 BESTCOMS Software BE1 CDS220 This page intentionally left blank...
Страница 424: ...ii Time Current Characteristics BE1 CDS220 This page intentionally left blank...
Страница 441: ...BE1 CDS220 Time Overcurrent Characteristic Curves A 17 Figure A 13 Time Characteristic Curve A Standard Inverse 99 1621...
Страница 442: ...A 18 Time Overcurrent Characteristic Curves BE1 CDS220 Figure A 14 Time Characteristic Curve B Very Inverse 99 1376...
Страница 443: ...BE1 CDS220 Time Overcurrent Characteristic Curves A 19 Figure A 15 Time Characteristic Curve C Extremely Inverse 99 1377...
Страница 444: ...A 20 Time Overcurrent Characteristic Curves BE1 CDS220 Figure A 16 Time Characteristic Curve G Long Time Inverse 99 1622...
Страница 452: ...ii Terminal Communication BE1 CDS220 This page intentionally left blank...
Страница 456: ...C 4 Terminal Communication BE1 CDS220 This page intentionally left blank...
Страница 458: ...ii Settings Calculations BE1 CDS220 This page intentionally left blank...
Страница 475: ......