BE1-CDS220 ASCII
Command
Interface
11-9
Example 3.
Read settings for all ports.
>SG-COM
SG-COM0=1200,P24,R1,X1
SG-COM1=9600,A0,P24,R1,X1
SG-COM2=19K,A156,P0,R1,X0
COMMAND SUMMARY
Miscellaneous Commands
ACCESS Command
Purpose:
Read/Set Access level in order to change settings
Syntax:
ACCESS[={password}]
Example:
ACCESS=CDS
Reference: Section
11,
ASCII Command Interface, Miscellaneous Command Descriptions
EXIT Command
Purpose:
Exit programming mode
Syntax:
EXIT - Note: Relay will prompt for verification
Example:
EXIT
Reference: Section
11,
ASCII Command Interface, Miscellaneous Command Descriptions
HELP Command
Purpose:
Obtain help on command operation
Syntax:
HELP {cmd} or H {cmd} for help on {cmd}, H1 for command list
Example:
HELP, H1, H SG-COM
Reference: Section
11,
ASCII Command Interface, Miscellaneous Command Descriptions
Metering Commands
M Command
Purpose:
Read all metered values in primary or secondary units
Syntax:
M[,P/,S] where P=primary, S=secondary
Example:
M or M,S
Reference: Section
5,
Metering
M-FREQ Command
Purpose:
Read measured frequency
Syntax:
M-FREQ
Example:
M-FREQ
Reference: Section
5,
Metering
M-I Command
Purpose:
Read metered currents (I) in primary or secondary units
Syntax:
M-I[G],[y] where y = P for primary, S for secondary
Example:
M-I or M-IG or M-I,S
Reference: Section
5,
Metering
M1-I Command
Purpose:
Read CT circuit #1 current primary or secondary units
Syntax:
M1[-I[p][y]] where p = A/B/C/N/Q, y=P for primary, S for secondary
Example:
M1 or M1-I or M1-IA
Reference: Section
5,
Metering
Содержание BE1-CDS220
Страница 2: ......
Страница 10: ...viii Introduction BE1 CDS220 This page intentionally left blank...
Страница 36: ...ii Quick Start BE1 CDS220 This page intentionally left blank...
Страница 48: ...ii Input And Output Functions BE1 CDS220 This page intentionally left blank...
Страница 66: ...iv Protection and Control BE1 CDS220 This page intentionally left blank...
Страница 112: ...ii Metering BE1 CDS220 This page intentionally left blank...
Страница 116: ...5 4 Metering BE1 CDS220 This page intentionally left blank...
Страница 166: ...ii BESTlogic Programmable Logic BE1 CDS220 This page intentionally left blank...
Страница 176: ...7 10 BESTlogic Programmable Logic BE1 CDS220 This page intentionally left blank...
Страница 234: ...8 56 Application BE1 CDS220 This page intentionally left blank...
Страница 236: ...ii Security BE1 CDS220 This page intentionally left blank...
Страница 240: ...9 4 Security BE1 CDS220 This page intentionally left blank...
Страница 242: ...ii Human Machine Interface BE1 CDS220 This page intentionally left blank...
Страница 256: ...10 14 Human Machine Interface BE1 CDS220 This page intentionally left blank...
Страница 258: ...ii ASCII Command Interface BE1 CDS220 This page intentionally left blank...
Страница 289: ...BE1 CDS220 Installation 12 7 Figure 12 8 MX Case Horizontal Panel Mount Front View Overall Dimensions...
Страница 422: ...14 32 BESTCOMS Software BE1 CDS220 This page intentionally left blank...
Страница 424: ...ii Time Current Characteristics BE1 CDS220 This page intentionally left blank...
Страница 441: ...BE1 CDS220 Time Overcurrent Characteristic Curves A 17 Figure A 13 Time Characteristic Curve A Standard Inverse 99 1621...
Страница 442: ...A 18 Time Overcurrent Characteristic Curves BE1 CDS220 Figure A 14 Time Characteristic Curve B Very Inverse 99 1376...
Страница 443: ...BE1 CDS220 Time Overcurrent Characteristic Curves A 19 Figure A 15 Time Characteristic Curve C Extremely Inverse 99 1377...
Страница 444: ...A 20 Time Overcurrent Characteristic Curves BE1 CDS220 Figure A 16 Time Characteristic Curve G Long Time Inverse 99 1622...
Страница 452: ...ii Terminal Communication BE1 CDS220 This page intentionally left blank...
Страница 456: ...C 4 Terminal Communication BE1 CDS220 This page intentionally left blank...
Страница 458: ...ii Settings Calculations BE1 CDS220 This page intentionally left blank...
Страница 475: ......