BE1-CDS220
Reporting and Alarm Functions
6-31
Figure 6-17. Reporting and Alarms Screen, Fault Recording Tab
Target settings are summarized in Table 6-16.
Table 6-16. Target Settings
Function Purpose
Enabled Targets
Specifies which protective elements will trigger a target. When the programmed
protective element’s BESTlogic expression is TRUE (1) and the trip output is
TRUE (1), a trip event is recorded in the target log.
Target Reset Logic
Logic expression that will reset the targets when TRUE.
Retrieving and Resetting Target Information
Target information can be obtained from the front panel HMI Screen 1.1.1, \STAT\TARGETS or through
the ASCII command interface using the RG-TARG (report general, targets) command. The target
information provided by the relay is from the most recent trip event. It is specific to an event and not
cumulative. The two most recent target reports are stored in nonvolatile memory. These two reports are
available from the front panel HMI Screen 4.1.1, \REPRT\FAULT\M_REC and 4.1.2, \REPRT\
FAULT\PREV. Targets for previous events are recorded in the fault summary reports, which are
described in detail later in this section.
When the relay trips and targets are logged for the event, the Trip LED is sealed-in on the front of the
relay and menu tree branch Screen 1.1.1, \STAT\TARGETS is automatically displayed on the LCD. See
Section 4, Human Machine Interface, for more information about the automatic display priority logic. The
display scrolls between the targets and the fault
current magnitudes that were recorded during the
fault. See the paragraphs on Fault Summary Reports
in this section for more information on how these fault
current magnitudes are recorded.
Pressing the Reset key on the HMI while the Target
Screen is displayed will clear these targets and the trip
LED. No password access is required to reset targets
from the front panel. After reset, the two most recent
target reports are still available from the HMI menu
branch 4, Reports. Password access is not required to
reset targets at the HMI.
Figure 6-18 illustrates the target reset logic.
TRSTKEY
Figure 6-18. Target Reset Logic
Содержание BE1-CDS220
Страница 2: ......
Страница 10: ...viii Introduction BE1 CDS220 This page intentionally left blank...
Страница 36: ...ii Quick Start BE1 CDS220 This page intentionally left blank...
Страница 48: ...ii Input And Output Functions BE1 CDS220 This page intentionally left blank...
Страница 66: ...iv Protection and Control BE1 CDS220 This page intentionally left blank...
Страница 112: ...ii Metering BE1 CDS220 This page intentionally left blank...
Страница 116: ...5 4 Metering BE1 CDS220 This page intentionally left blank...
Страница 166: ...ii BESTlogic Programmable Logic BE1 CDS220 This page intentionally left blank...
Страница 176: ...7 10 BESTlogic Programmable Logic BE1 CDS220 This page intentionally left blank...
Страница 234: ...8 56 Application BE1 CDS220 This page intentionally left blank...
Страница 236: ...ii Security BE1 CDS220 This page intentionally left blank...
Страница 240: ...9 4 Security BE1 CDS220 This page intentionally left blank...
Страница 242: ...ii Human Machine Interface BE1 CDS220 This page intentionally left blank...
Страница 256: ...10 14 Human Machine Interface BE1 CDS220 This page intentionally left blank...
Страница 258: ...ii ASCII Command Interface BE1 CDS220 This page intentionally left blank...
Страница 289: ...BE1 CDS220 Installation 12 7 Figure 12 8 MX Case Horizontal Panel Mount Front View Overall Dimensions...
Страница 422: ...14 32 BESTCOMS Software BE1 CDS220 This page intentionally left blank...
Страница 424: ...ii Time Current Characteristics BE1 CDS220 This page intentionally left blank...
Страница 441: ...BE1 CDS220 Time Overcurrent Characteristic Curves A 17 Figure A 13 Time Characteristic Curve A Standard Inverse 99 1621...
Страница 442: ...A 18 Time Overcurrent Characteristic Curves BE1 CDS220 Figure A 14 Time Characteristic Curve B Very Inverse 99 1376...
Страница 443: ...BE1 CDS220 Time Overcurrent Characteristic Curves A 19 Figure A 15 Time Characteristic Curve C Extremely Inverse 99 1377...
Страница 444: ...A 20 Time Overcurrent Characteristic Curves BE1 CDS220 Figure A 16 Time Characteristic Curve G Long Time Inverse 99 1622...
Страница 452: ...ii Terminal Communication BE1 CDS220 This page intentionally left blank...
Страница 456: ...C 4 Terminal Communication BE1 CDS220 This page intentionally left blank...
Страница 458: ...ii Settings Calculations BE1 CDS220 This page intentionally left blank...
Страница 475: ......