BE1-CDS220 ASCII
Command
Interface
11-15
RO Command
Purpose:
Read Oscillographic COMTRADE .DAT/.CFG/.HDR Fault Report
Syntax:
RO-nA/B[#].CFG/DAT/HDR where n=report number,A=ASCII/B=BINARY,#=OSC 1/2
Example:
RO-3A1.CFG or RO-3A1.DAT or RO-5B2.CFG or RO-5B2.DAT or RO-5A.HDR
Reference: Section
6,
Reporting and Alarm Functions, Fault Reporting
RS Command
Purpose:
Read/Reset Sequence of Events Record Data
Syntax:
RS[-n/Fn/ALM/IO/LGC/NEW][=0] where n=# of events and Fn=fault record #
Example:
RS (displays a directory of all event records in memory)
RS-23 (view SER report for last 23 events)
RS-F12 (view SER report associated with fault record 12)
RS-ALM (view all SER report ALARM events since RS=0 reset)
RS-IO (view all SER report INPUT OUTPUT events since RS=0 reset)
RS-LGC (view all SER report LOGIC events since RS=0 reset)
RS-NEW (view all SER report events since RS=0 reset)
RS=0 (reset NEW records counter)
Reference: Section
6,
Reporting and Alarm Functions, Sequence of Events Recorder Function
RT Command
Purpose:
Read Transformer Duty Status
Syntax:
RT
Example:
RT
Reference: Section
6,
Reporting and Alarm Functions, Transformer Monitoring
RT-DUTY Command
Purpose:
Read/Set Transformer through Fault Duty Log
Syntax:
RT-DUTY[{phase}[={%duty}]] where %duty is % of dmax set with ST-DUTY
Example:
RT-DUTYA or RT-DUTYB=50
Reference: Section
6,
Reporting and Alarm Functions, Transformer Monitoring
RT-TFCNTR Command
Purpose:
Read/Set Transformer through Fault Counter
Syntax:
RT-TFCNTR[={#operations}]
Example:
RT-TFCNTR=32 or RT-TFCNTR=652
Reference: Section
6,
Reporting and Alarm Functions, Transformer Monitoring
Setting Command
S Command
Purpose:
Read all relay setting parameters
Syntax:
S
Example:
S
Reference: Section
11,
ASCII Command Interface, Settings (S) Command Descriptions
Alarm Setting Commands
SA Command
Purpose:
Read all alarm settings for Major, Minor and Logic alarms
Syntax:
SA
Example:
SA
Reference: Section
6,
Reporting and Alarm Functions, Alarms Function
Содержание BE1-CDS220
Страница 2: ......
Страница 10: ...viii Introduction BE1 CDS220 This page intentionally left blank...
Страница 36: ...ii Quick Start BE1 CDS220 This page intentionally left blank...
Страница 48: ...ii Input And Output Functions BE1 CDS220 This page intentionally left blank...
Страница 66: ...iv Protection and Control BE1 CDS220 This page intentionally left blank...
Страница 112: ...ii Metering BE1 CDS220 This page intentionally left blank...
Страница 116: ...5 4 Metering BE1 CDS220 This page intentionally left blank...
Страница 166: ...ii BESTlogic Programmable Logic BE1 CDS220 This page intentionally left blank...
Страница 176: ...7 10 BESTlogic Programmable Logic BE1 CDS220 This page intentionally left blank...
Страница 234: ...8 56 Application BE1 CDS220 This page intentionally left blank...
Страница 236: ...ii Security BE1 CDS220 This page intentionally left blank...
Страница 240: ...9 4 Security BE1 CDS220 This page intentionally left blank...
Страница 242: ...ii Human Machine Interface BE1 CDS220 This page intentionally left blank...
Страница 256: ...10 14 Human Machine Interface BE1 CDS220 This page intentionally left blank...
Страница 258: ...ii ASCII Command Interface BE1 CDS220 This page intentionally left blank...
Страница 289: ...BE1 CDS220 Installation 12 7 Figure 12 8 MX Case Horizontal Panel Mount Front View Overall Dimensions...
Страница 422: ...14 32 BESTCOMS Software BE1 CDS220 This page intentionally left blank...
Страница 424: ...ii Time Current Characteristics BE1 CDS220 This page intentionally left blank...
Страница 441: ...BE1 CDS220 Time Overcurrent Characteristic Curves A 17 Figure A 13 Time Characteristic Curve A Standard Inverse 99 1621...
Страница 442: ...A 18 Time Overcurrent Characteristic Curves BE1 CDS220 Figure A 14 Time Characteristic Curve B Very Inverse 99 1376...
Страница 443: ...BE1 CDS220 Time Overcurrent Characteristic Curves A 19 Figure A 15 Time Characteristic Curve C Extremely Inverse 99 1377...
Страница 444: ...A 20 Time Overcurrent Characteristic Curves BE1 CDS220 Figure A 16 Time Characteristic Curve G Long Time Inverse 99 1622...
Страница 452: ...ii Terminal Communication BE1 CDS220 This page intentionally left blank...
Страница 456: ...C 4 Terminal Communication BE1 CDS220 This page intentionally left blank...
Страница 458: ...ii Settings Calculations BE1 CDS220 This page intentionally left blank...
Страница 475: ......