VAR4 / VAR12 / VAR20 - Operation Manual
Is
Page 137 of 308
sue: 03 complete, approved
7.4.2
PTT Button Cough Timeout Configuration
The cough timeout is the time length the PTT button may be released before the route is closed down. When
this is enabled, the audio path is muted immediately when the PTT button is released, allowing the operator
to cough without it being broadcast. If the PTT button is then re-pressed within the cough time, the
announcement will continue as normal.
In order to configure the cough timeout proceed as follows.
1. Select
Configuration
Æ
System
Æ
Router
Æ
Inputs
Æ
Mic/Line
.
2. Scroll the Mic/Line input list and select the required input:
[I/P #01 – MIC/LINE 01]
Default value:
input 1
Possible inputs: 01 to 04 for VAR4
01 to 12 for VAR12
01 to 20 for VAR20
Note:
The input name is shown on the right side of the display. The input name above is the Mic/Line
input 1 default name, however this may have been changed according to each site’s
configuration.
3. The configured Mic/Line type is displayed.
The input type may be changed, as described in Section “
7.1 Mic/Line Input Type Configuration
”.
4. Press the SELECT key to display the next sub-menu.
5. Move to, and select the
PTT
menu item.
[PTT] Audio Ctrl Name
Note:
‘PTT’ menu item is only available for Single Button Microphone.
6. Move to, and select the
Cough
menu item.
PTT Zones [Cough]
7. Scroll the cough timeouts until the required value is displayed:
[Cough (10th Sec) 0]
Default value:
‘0’
Possible values: 0 to 50. This value is the cough timeout in tenths of a second, so divide by ten for the
cough timeout in seconds.
Note:
The rotary encoder can be used to adjust the cough time in 0.1s increments.
8. Save the changes by pressing the SELECT key, or cancel by pressing the BACK key.