VAR4 / VAR12 / VAR20 - Operation Manual
Is
Page 43 of 308
sue: 03 complete, approved
5.5 Temperature
The VAR Router has an over-temperature alarm, and it is possible to configure the internal temperature at
which this alarm is raised by following these steps.
1. Select
Configuration
Æ
System
Æ
Misc
Æ
Temp
.
2. Move to, and toggle to the required option in the left field:
[Not Conf] Max Temp(°C)=70
•
Not Conf
No fault will be reported.
•
Config’d
A fault will be reported if the temperature exceeds the configured maximum.
Default value:
‘Not-Conf’
3. Move to, and scroll the temperature field until the required threshold temperature is displayed.
Config’d [Max Temp(°C)=70]
Default value:
‘70’ °C
Possible values: 15 to 99°C
4. Save the changes by pressing the SELECT key, or cancel by pressing the BACK key.
5.6
RS-232 Asynchronous Port
The RS232 port is used to connect to equipment such as PC/DVA system, and to PCs running remote fault
reporting software and the ASL Configuration Tool.
It is possible to define whether the RS232 port connection is direct or via a modem, and whether or not to
implement hardware flow control (i.e. suspend transmission when CTS is not asserted).
The default communications parameters are: 9600 bps, no parity, 8 data bits, 1 stop bit.
In order to configure the RS232 port proceed as follows.
1. Select
Configuration
Æ
System
Æ
Misc
Æ
Async-Port
.
2. Move to, and toggle to the required CTS option in the left field:
[CTS disabled] Direct Connect
•
CTS disabled
Hardware flow control is not implemented.
•
CTS enabled
Hardware flow control is implemented.
Default value:
‘CTS disabled’