VAR4 / VAR12 / VAR20 - Operation Manual
Is
Page 275 of 308
18.5.2 Amplifier
Detailed
Status
2. Scroll and select a mainframe from the list:
[Frame#nn - ]
sue: 03 complete, approved
The amplifier detailed status can be displayed, as described in the following steps.
1. Select
Tests
Æ
Status
.
Mainframe: 01 to 63
Note:
Only configured mainframes are displayed.
The mainframe description will be shown on the right side of the display, if defined.
3. Move to, scroll, and select an amplifier from the slot list in the left field:
DIP = 000000 Measured [Slot#1]
Slot: 1 to 4
4. Move to, and select the
I/O
menu item:
Type [I/O] Measured
5. The amplifier detailed status is displayed {0|1}:
[Swap=0 Lockout=0 Sleep=0 Monitor=0]
Where:
Swap=1
indicates amplifier swapped to standby.
Lockout=1 indicates amplifier standby lock out is active, i.e. another amplifier has taken standby
amplifier associated with the amplifier being viewed.
Sleep=1
indicates the amplifier is in sleep mode.
Monitor=1 indicates the amplifier is connected to the audio monitor bus.
Note:
A warning message will be displayed if an unused slot is selected.
6. Return to the parent menu by pressing the SELECT key, or the BACK key.