Mute Input Configuration
The Mute input is a special input, which mutes even fire microphones if needed. For this purpose its priority
is set to ‘0’ by default. However, the mute input is configurable, so it is possible to mute just DVAs, and/or
any other inputs on a priority basis.
The Mute input can be routed by activation of a contact or a button configured for DVA routing. For
configuration, refer to Sections “
14.2 Configuring a Contact for Routing
”, “
16.3.2 Configuring a Digital Input
(Contact) for Routing
”, and “
7.3.4.3 Configuring a Button for DVA Routing
”.
The following table summarises the configurable input parameters, and indicates those parameters available
for the Mute input with a tick (
9
). Each parameter configuration is described in the following sections.
Table 12
Configurable Mute Input Parameters
Input Type
Surv EQ Fade Chime Gain
O/P
Gains
Pri
Phantom
Power
Class Name Buttons ANS
Mute
X X
X
X
X
X
9
X
9
X
X
9
10.1
Mute Input Emergency Class
The emergency class is used to indicate the emergency DVA message status, as described in Section “
8.4
DVA Input Emergency Class
”.
Ensure that the Mute input class is set to ‘Non Emergency’ following these steps.
1. Select
Configuration
Æ
System
Æ
Router
Æ
Inputs
Æ
Music/Mute
Æ
Mute
Æ
Class
.
From V4.1.0470 or later:
Configuration
Æ
System
Æ
Router
Æ
Inputs
Æ
Misc
Æ
Mute
Æ
Class
2. Scroll the list until ‘Non Emergency’ is displayed:
[Non Emergency]
3. Save the changes by pressing the SELECT key, or cancel by pressing the BACK key.