7.3.4.3.5
DVA Routing Button Busy Indication Configuration
It is also possible to configure whether or not the route associated with a ‘DVA Routing’ button should cause
a busy indication on the LEDs associated with microphone zone select buttons. If for instance this routing
were used for background music control, then the busy LEDs would not be lit. If another type of route were
being made, then the busy LEDs would normally be lit.
In order to configure the busy indication proceed as follows.
1. Select
Configuration
Æ
System
Æ
Router
Æ
Inputs
Æ
Mic/Line
.
2. Scroll the Mic/Line input list and select the required input:
[I/P #01 – MIC/LINE 01]
Default value:
input 1
Possible inputs: 01 to 04 for VAR4
01 to 12 for VAR12
01 to 20 for VAR20
Note:
The input name is shown on the right side of the display. The input name above is the Mic/Line
input 1 default name, however this may have been changed according to each site’s
configuration.
3. The configured Mic/Line type is displayed.
The input type may be changed, as described in Section “
7.1 Mic/Line Input Type Configuration
”.
4. Press the SELECT key to display the next sub-menu.
5. Move to, and select the
Buttons
menu item.
[Buttons] Audio Ctrl Name
Note:
The ‘Buttons’ menu item is only available for Paging and Zoned Fire Microphones.
6. Move to, and select the
Zoning
menu item.
PTT [Zoning] Switches Cough
7. Move to, and scroll the button list until the required button is displayed in the left field:
[Button #01] Not-Conf Security
Default value:
‘Button #01’
Button numbers: 01 to 30
8. Press the SELECT key to display the next sub-menu.
9. Move to, and select the
Control
menu item to display the next sub-menu:
Zoning [Control] Clear-all