VAR4 / VAR12 / VAR20 - Operation Manual
Is
Page 270 of 308
1. Select
Tests
Æ
Status
.
3. Move to, and select the
Measured
menu item.
sue: 03 complete, approved
18.4.2
Mainframe Battery Voltage
The battery voltage presented to the mainframe can be displayed, as described in the following steps.
2. Scroll and select a mainframe from the list:
[Frame#nn - ]
Mainframe: 01 to 63
Note:
Only configured mainframes are displayed.
The mainframe description will be shown on the right side, if defined.
DIP = 000000 [Measured] Slot#1
4. Move to, and select the
BAT
menu item:
[BAT] B1 B2 DC1 DC2 AUX Temp
5. The battery voltage is displayed:
[Raw Battery Volts= 23.2]
6. Return to the parent menu by pressing the SELECT key, or the BACK key.
18.4.3
Battery Voltage Feeding Slots 1 and 2
The battery voltage feeding slots 1 and 2 in a mainframe can be displayed, as described in the following
steps.
1. Select
Tests
Æ
Status
.
2. Scroll and select a mainframe from the list:
[Frame#nn - ]
Mainframe: 01 to 63
Note:
Only configured mainframes are displayed.
The mainframe description will be shown on the right side, if defined.
3. Move to, and select the
Measured
menu item.
DIP = 000000 [Measured] Slot#1
4. Move to, and select the
B1
menu item:
BAT [B1] B2 DC1 DC2 AUX Temp
5. The battery voltage is displayed:
[Battery Monitor 1 Volts= 22.1]
6. Return to the parent menu by pressing the SELECT key, or the BACK key.