VAR4 / VAR12 / VAR20 - Operation Manual
Is
Page 188 of 308
•
Panel
sue: 03 complete, approved
13.6
Induction Loop Parameter Configuration
13.6.1
Configuring the Induction Loop Type
In order to configure the induction loop type proceed as follows.
1. Select
Configuration
Æ
System
Æ
Router
Æ
Outputs
Æ
Configuration
.
2. Scroll the output list and select the required induction loop output:
[O/P #1 - OUTPUT 01]
Default value:
output 1
Outputs:
4 outputs for VAR4
12 outputs for VAR12
20 outputs for VAR20
Note:
Not all of the VAR Router’s outputs can be configured to support Induction Loops;
Table 14
details the possible induction loop output allocation.
The output name is shown on the right side of the display. The output name above is the
output 1 default name, however this may have been changed according to each site’s
configuration.
3. Move to, and select the
Ind Loop
menu item.
Level [Ind Loop] Surv Override Name
4. Scroll the induction loop types until the required value is displayed:
[Ind Loop Type = Panel]
Induction Loop panels typically installed in Ticket Hall, platform, concourse, and passageways.
An example is the ASL ILP01 Induction Loop Panel.
•
Other
For applications where low frequency cut is required. The equalisation gain setting provides the
gain reduction for the selected band; see Section “
13.6.2 Equalisation Configuration
”.
Default value:
‘Panel’
5. Save the changes by pressing the SELECT key, or cancel by pressing the BACK key.
Proceed with the induction loop configuration in the following sections according to the selected type.