VAR4 / VAR12 / VAR20 - Operation Manual
sue: 03 complete, approved
oved
Is
Page 223 of 308
Page 223 of 308
16.2.2
Configuring an Analogue Input as Programme Selector
16.2.2
Configuring an Analogue Input as Programme Selector
The application of the Programme Selector function is to allow remote selection of alternative sources to a
specific zone or zones. Normally the Programme Selector unit will be mounted within the zone and allow
selection of alternative sources, typically music sources.
The application of the Programme Selector function is to allow remote selection of alternative sources to a
specific zone or zones. Normally the Programme Selector unit will be mounted within the zone and allow
selection of alternative sources, typically music sources.
As such it is possible to assign a particular Programme Selector to be associated with one, or any group of,
VAR Router outputs.
As such it is possible to assign a particular Programme Selector to be associated with one, or any group of,
VAR Router outputs.
That having been done it is then possible, for each position of the Programme Selector, to assign which input
it corresponds to.
That having been done it is then possible, for each position of the Programme Selector, to assign which input
it corresponds to.
Programme Selectors provide 12 position switch with ‘1’ providing an ‘off’ position. Normally this would
correspond to all routes being ‘off’.
Programme Selectors provide 12 position switch with ‘1’ providing an ‘off’ position. Normally this would
correspond to all routes being ‘off’.
L
L
•
When an analogue input is used as a selector, zones to which inputs are routed by the
selector will not show as busy on microphones.
•
When an analogue input is used as a selector, zones to which inputs are routed by the
selector will not show as busy on microphones.
•
In the event of a fault (connection failure to the Programme Selector or RS485
communications failure to the Remote I/O unit), the routing defaults to that set-up on
position 1.
•
In the event of a fault (connection failure to the Programme Selector or RS485
communications failure to the Remote I/O unit), the routing defaults to that set-up on
position 1.
In order to configure an analogue input as Program Selector proceed as follows.
1. Select
Configuration
Æ
System
Æ
Router
Æ
Control
Æ
Remote
.
2. Move to scroll the Remote I/O unit list until the required unit is displayed:
[Remote I/O unit=n] Not Configured
Default value:
‘Remote I/O unit=1’
Possible I/O units: 1 to 3 for VAR4
1 to 6 for VAR12
1 to 9 for VAR20
3. Move to, and select the
Analogue
menu item.
[Analogue] Digital In Digital Out
4. Scroll the analogue input list and select the required input:
[Analogue channel=nn]
Default value:
‘Analogue channel=1’
Possible I/O units: 1 to 12
•
Make sure the selected analogue input is to be configured as Programme Selector.
Once the ‘Selector’ menu item is selected, it will be assigned to the analogue input and
the previous configuration will be lost.
•
The currently assigned configuration is displayed in upper-case letters.
!
!
Содержание VAR12
Страница 308: ......