VAR4 / VAR12 / VAR20 - Operation Manual
Is
Page 241 of 308
sue: 03 complete, approved
16.3.2.1
Configuring the Zone Selection for a Routing Digital Input (Contact)
Once a contact is configured for ‘Routing’, it is necessary to define the route or routes that it controls, by
associating an input to each available output, as described in the following steps.
1. Select
Configuration
Æ
System
Æ
Router
Æ
Control
Æ
Remote
.
2. Move to scroll the Remote I/O unit list until the required unit is displayed:
[Remote I/O unit=n] Not Configured
Default value:
‘Remote I/O unit=1’
Possible I/O units: 1 to 3 for VAR4
1 to 6 for VAR12
1 to 9 for VAR20
3. Move to, and select the
Digital In
menu item.
Analogue [Digital In] Digital Out
4. Move to, and scroll the contact list until the required contact is displayed in the left field:
[Contact#nn] Routing Not-Surv
Default value:
‘Contact#01’
Contact numbers: 01 to 12
5. Press the SELECT key to display the routing configuration menu.
6. Move to, and select the
Zoning
menu item:
[Zoning] Control Clear-all
7. Move to, and scroll the output list until the required output is displayed in the left field:
[OUTPUT 01] Not-Conf
Default value:
output 1 name
Outputs:
4 output for VAR4
12 output for VAR12
20 output for VAR20
Note:
The output given above is the output 1 default name, however this may have been changed
according to each site’s configuration.
8. Move to, and scroll the right field list until the required input is displayed:
OUTPUT 01 [Not-Conf]
•
[Not-Conf]
No route associated with the output.
•
[MIC/LINE 01]
The output is routed to this particular input.