VAR4 / VAR12 / VAR20 - Operation Manual
Is
Page 284 of 308
sue: 03 complete, approved
20.4 Fault
Log
The unit maintains a time-stamped 200 event fault log in non-volatile memory, this include event acceptance
and clearance, and user logging in and out times. The non-volatile memory has an endurance of greater
than 100,000 cycles.
All faults are logged on separate mainframe fault logs for mainframe-specific faults retained by each
mainframe and a single system fault log retained by the VAR Router, which stores all faults (200 events).
To prevent intermittent or frequently recurring faults from rapidly causing excessive write operations to the
memory, faults are latched so that a recurring fault is logged in its first instance, and thereafter any
repetitions are not recorded, unless a physical manual fault ‘clear’ has taken place.
The fault log is continuously checked, and, if it is found to be corrupted, it is erased and a new ‘LOG
CLEARED’ fault is logged. A manual fault log clearing function is also provided.
20.4.1
System Fault Log
The system fault log (history of the last 200 faults) can be viewed, as described in the following steps.
1. Select
Faults
Æ
Logs
Æ
System
.
2. Scroll the fault log to view the fault history:
[12Oct2006 14:10 IP03 MIC COMMS ]
Default value:
Most recent record (001/nnn)
Note:
(record number/ total number of records) is displayed on the first line right field.
3. Return to the parent menu by pressing the BACK key
20.4.2
Mainframe Fault Log
The fault log maintained by a specific mainframe can be viewed, as described in the following steps.
1. Select
Faults
Æ
Logs
.
2. Scroll and select a mainframe from the list:
System [Frame#nn]
Mainframe: 01 to 63
Note:
Only configured mainframes are displayed.
3. Scroll the fault log until the required fault is displayed:
[12Oct2006 12:10 F24/S2 AMP FAIL ]
Default value:
Most recent record (001/nnn)
Note:
(record number/ total number of records) is displayed on the first line right field.
4. Press SELECT key to give more detail if available.
5. Return to the parent menu by pressing the BACK key
Содержание VAR12