8.3
DVA Input Priority Configuration
The input priority is used to resolve conflicts when two or more inputs try to broadcast to the same output. In
this case the input with the highest priority will be able to broadcast, and the others will not.
Priority is assignable to each input per output. This is so that different inputs may have different priorities
according to which zone they are serving. For example a particular audio input may have a high priority only
in its local zone.
A lower priority DVA may be overridden during broadcast if a higher priority input starts to access the zone.
In this case, the lower priority DVA will however be able to continue broadcasting to any remaining zones.
If a DVA is overridden the action is different to if Mic/Line input sources are overrriden. The DVA is silenced
immediately in the zone(s) in which it is overridden, and then when the override is removed it is re-instated
immediately, i.e. does not wait until the beginning of the cycle. This operation is used for DVAs because in
many cases DVAs are used for repeating emergency announcements.
L
•
19 priority levels are assignable to any of the DVA inputs.
•
Assignment of equal priorities means that those inputs operate on a ‘first-come-first-served’
basis.
•
The lower the priority value, the higher the priority.
In order to set a DVA input priority proceed as follows.
1. Select
Configuration
Æ
System
Æ
Router
Æ
Inputs
Æ
DVA
.
2. Scroll the DVA input list until the required DVA is displayed:
[EVAC 01]
Default value:
DVA input 1 name
Possible DVAs: VAR4: EVAC 01 to EVAC 02 (inputs 1 to 2, long DVA)
TEST 01 to TEST 02 (inputs 3 to 4, short DVA)
VAR12: EVAC 01 to EVAC 04 (inputs 1 to 4, long DVA)
TEST 01 to TEST 04 (inputs 5 to 8, short DVA)
VAR20: EVAC 01 to EVAC 06 (inputs 1 to 6, long DVA)
TEST 01 to TEST 06 (inputs 6 to 12, short DVA)
Note:
The DVA input names given above are the default names, however these may be changed
according to each site’s configuration.
3. Move to, and select the
Pri
menu item:
[Pri] Class Gain O/pGains Name
4. Move to, and scroll the output list until the required output is displayed in the left field:
[OUTPUT 01] Priority-03
Default value:
output 1 name
Outputs:
4 output for VAR4
12 output for VAR12
20 output for VAR20
Note:
The output given above is the output 1 default name, however this may have been changed
according to each site’s configuration.