VAR4 / VAR12 / VAR20 - Operation Manual
Is
Page 269 of 308
1. Select
Tests
Æ
Status
.
[Frame#nn - ]
The mainframe description will be shown on the right side, if defined.
3. DIP field displays 6 data bits {0|1} which indicate the settings of the mainframe DIP switches 1 to 6
inclusive:
Note:
DIP = SW6 SW5 SW4 SW3 SW2 SW1
Where:
0 = Switch OFF, 1 = Switch ON
SW1: deep discharge disconnect enable
1 = Automatically switch off the amplifier mainframe if the standby battery supply
voltage drops below 21V.
SW2: mains fault reporting enable
0 = The mainframe is being supplied from batteries only (no AC mains).
SW3: battery fault reporting enable
0 = The mainframe is being supplied from AC mains only (no batteries).
SW4: AUX supply fault reporting enable
1 = Full compliance with BS5839:Part 8:1998 and BS EN60849:1998.
SW5: mainframe CPU faults latching
0 = Mainframe CPU faults not latched by the front panel LED.
sue: 03 complete, approved
18.4 Mainframe
Status
Various measurements from the mainframe are available such as voltages, temperature readings, etc. The
following sections describe the available measurements.
18.4.1
Mainframe Dip Switch Settings
The settings of the mainframe DIP switches 1 to 6 can be displayed, as described in the following steps.
2. Scroll and select a mainframe from the list:
Mainframe: 01 to 63
Note:
Only configured mainframes are displayed.
[DIP = 000000] Measured Slot#1
SW6: not used
4. Return to the parent menu by pressing the SELECT key, or the BACK key.