VAR4 / VAR12 / VAR20 - Operation Manual
Is
Page 228 of 308
sue: 03 complete, approved
5. Move to, and select the
Volume
menu item:
UNUSED Selector [Volume] Fault ANS
Other options available:
•
Unused
Select this option if the analogue input is not connected.
See Section “
16.2.1 Configuring an Analogue Input as Unused
”.
•
Selector
Assign the selected analogue input as Programme Selector.
See Section “
16.2.2 Configuring an Analogue Input as Programme Selector
”.
•
Fault
Assign the selected analogue input as Fault Input.
See Section “
16.2.4 Configuring an Analogue Input as Fault Input
”.
•
ANS
Assign the selected analogue input as Ambient Noise Sensor (ANS).
See Section “
16.2.5 Configuring an Analogue Input as Ambient Noise Sensor (ANS)
”.
6. Move to, and scroll the output list until the required output is displayed in the left field:
[OUTPUT 01] Not Selected
Default values: output 1 name
Outputs:
4 output for VAR4
12 output for VAR12
20 output for VAR20
Note:
The output given above is the output 1 default name, however this may have been changed
according to each site’s configuration.
7. Move to, and toggle to the required selection option in the right field:
OUTPUT 01 [Not Selected]
•
[Not Selected]
The output is not controlled by the Volume Control.
•
[Selected]
The output is controlled by the Volume Control. Any input configured to the Volume Control will
have the volume affected when routed to this output.
Default value:
‘Not-Selected’
8. Repeat
steps
6
to
7
to configure each output.
9. Save the changes by pressing the SELECT key, or cancel by pressing the BACK key.
10. Pressing the SELECT key will display a sub-menu which allows the user to select the inputs controlled
by the Volume Control.