VAR4 / VAR12 / VAR20 - Operation Manual
Is
Page 127 of 308
sue: 03 complete, approved
7.3.4.3.6
DVA Routing Button DVA Play Mode Configuration
This setting is only relevant when a ‘DVA Routing’ button is used for control of DVA routes.
The DVAs assigned to a button may be configured to cease playing immediately that the route is terminated
(DVA-Part), or play until the end of the message and then stop (DVA-Full).
In order to set the DVA play mode proceed as follows.
1. Select
Configuration
Æ
System
Æ
Router
Æ
Inputs
Æ
Mic/Line
.
2. Scroll the Mic/Line input list and select the required input:
[I/P #01 – MIC/LINE 01]
Default value:
input 1
Possible inputs: 01 to 04 for VAR4
01 to 12 for VAR12
01 to 20 for VAR20
Note:
The input name is shown on the right side of the display. The input name above is the Mic/Line
input 1 default name, however this may have been changed according to each site’s
configuration.
3. The configured Mic/Line type is displayed.
The input type may be changed, as described in Section “
7.1 Mic/Line Input Type Configuration
”.
4. Press the SELECT key to display the next sub-menu.
5. Move to, and select the
Buttons
menu item.
[Buttons] Audio Ctrl Name
Note:
The ‘Buttons’ menu item is only available for Paging and Zoned Fire Microphones.
6. Move to, and select the
Zoning
menu item.
PTT [Zoning] Switches Cough
7. Move to, and scroll the button list until the required button is displayed in the left field:
[Button #01] Not-Conf Security
Default value:
‘Button #01’
Button numbers: 01 to 30
8. Press the SELECT key to display the next sub-menu.
9. Move to, and select the
Control
menu item to display the next sub-menu:
Zoning [Control] Clear-all
Содержание VAR12