VAR4 / VAR12 / VAR20 - Operation Manual
Is
Page 199 of 308
14.2.1
Configuring the Zone Selection for a Routing Contact
Once a contact is configured for ‘Routing’, it is necessary to define the route or routes that it controls, by
associating an input to each available output, as described in the following steps.
Default value:
‘Contact#01’
sue: 03 complete, approved
1. Select
Configuration
Æ
System
Æ
Router
Æ
Control
Æ
Contacts
.
2. Move to, and scroll the contact list until the required contact is displayed in the left field:
[Contact#nn] Routing Not-Surv
Contact numbers: 01 to 22 for VAR4
01 to 42 for VAR12
01 to 62 for VAR20
Where contacts: 00 to 10 are analogue
11 to 62 are opto-isolated
3. Press the SELECT key to display the routing configuration menu.
4. Move to, and select the
Zoning
menu item:
[Zoning] Control Clear-all
5. Move to, and scroll the output list until the required output is displayed in the left field:
[OUTPUT 01] Not-Conf
Default value:
output 1 name
Outputs:
4 output for VAR4
12 output for VAR12
20 output for VAR20
Note:
The output given above is the output 1 default name, however this may have been changed
according to each site’s configuration.
6. Move to, and scroll the right field list until the required input is displayed:
OUTPUT 01 [Not-Conf]
•
[Not-Conf]
No route associated with the output.
•
[MIC/LINE 01]
The output is routed to this particular input.
Default value:
‘Not-Conf’
Inputs:
VAR4:
Local inputs: 4 Mic/Line 4 DVAs + 1 music + Mute + Test Tone
VAR12: Local inputs: 12 Mic/Line 8 DVAs + 1 music + Mute + Test Tone
Network inputs: 8 Mic/Line 4 DVAs + 1 music + Mute + Test Tone
VAR20: Local inputs: 20 Mic/Line 12 DVAs + 1 music + Mute + Test Tone
Network inputs: 8 Mic/Line 4 DVAs + 1 music + Mute + Test Tone