VAR4 / VAR12 / VAR20 - Operation Manual
Is
Page 234 of 308
sue: 03 complete, approved
5. Move to, and select the
Ans
menu item:
UNUSED Selector Volume Fault [Ans]
Other options available:
•
Unused
Select this option if the analogue input is not connected.
See Section “
16.2.1 Configuring an Analogue Input as Unused
”.
•
Selector
Assign the selected analogue input as Programme Selector.
See Section “
16.2.2 Configuring an Analogue Input as Programme Selector
”.
•
Volume
Assign the selected analogue input as Volume Control.
See Section “
16.2.3 Configuring an Analogue Input as Volume Control
”
•
Fault
Assign the selected analogue input as Fault Input.
See Section “
16.2.4 Configuring an Analogue Input as Fault Input
”.
6. Move to, and scroll the output list until the required output is displayed in the left field:
[OUTPUT 01] Not Selected
Default values: output 1 name
Outputs:
4 output for VAR4
12 output for VAR12
20 output for VAR20
Note:
The output given above is the output 1 default name, however this may have been changed
according to each site’s configuration.
7. Move to, and toggle to the required selection option in the right field:
OUTPUT 01 [Not Selected]
•
[Not Selected]
The output is not controlled by the ANS Sensor.
•
[Selected]
The output gain is controlled by the ANS Sensor, and modified in response to changes in ambient
noise level.
Default value:
‘Not-Selected’
8. Repeat
steps
6
to
7
to configure each output.
9. Save the changes by pressing the SELECT key, or cancel by pressing the BACK key.