VAR4 / VAR12 / VAR20 - Operation Manual
Is
Page 54 of 308
sue: 03 complete, approved
6.2
Viewing Configured Mainframes
6.2.1 Verbose
View
The verbose view provides a mainframe’s software version, as well as each amplifier’s software version
number, power rating, and surveillance mode.
In order to view the details of an amplifier mainframe proceed as follows.
1. Select
Configuration
Æ
System
Æ
View
Æ
Verbose
.
2. The configured mainframes are displayed:
[Frame02 v1.2] Slot1 v23.4 100W Standby
Note:
If no mainframe is configured, then a warning message will be displayed.
If the software version is available, then is shown as in the above example, else ‘V?.?’ is
displayed.
‘Standby’:
identifies a standby amplifier
‘Single’: identifies a single circuit surveillance mode
‘Dual’:
identifies a dual circuit surveillance mode
‘Loop’: identifies a loop return surveillance mode
Pressing the DEFAULT key will display the Slot 1 configuration.
3. Scroll the mainframe list (left field) to view another mainframe configuration, or scroll the slot field (right
field) to view a different slot configuration within the currently selected mainframe:
Frame02 v1.2 [Slot1 v23.4 100W Standby]
4. Return to the parent menu by pressing the SELECT or BACK keys.