VAR4 / VAR12 / VAR20 - Operation Manual
Is
Page 209 of 308
3. Press the SELECT key to display the routing configuration menu.
sue: 03 complete, approved
14.2.6
Routing Contact DVA Play Mode Configuration
This setting is only relevant when a ‘Routing’ contact is used for control of DVA routes.
The DVAs assigned to a contact may be configured to cease playing immediately that the route is terminated
(DVA-Part), or play until the end of the message and then stop (DVA-Full).
In order to set the DVA play mode proceed as follows.
1. Select
Configuration
Æ
System
Æ
Router
Æ
Control
Æ
Contacts
.
2. Move to, and scroll the contact list until the required contact is displayed in the left field:
[Contact#nn] Routing Not-Surv
Default value:
‘Contact#01’
Contact numbers: 01 to 22 for VAR4
01 to 42 for VAR12
01 to 62 for VAR20
Where contacts: 00 to 10 are analogue
11 to 62 are opto-isolated
4. Move to, and select the
Control
menu item:
Zoning [Control] Clear-all
5. Move to, and toggle to the required play mode in the right field:
Latching Busy=On [DVA-Full]
•
[DVA-Full]
The repeating DVA broadcast will play to the end of the message before stopping when the trigger
is de-asserted.
•
[DVA-Part]
The repeating DVA broadcast will stop immediately when the trigger is de-asserted.
Default value:
‘DVA-Full’
Note:
If the Routing contact is configured to Play Once, this setting should be DVA-Full.
6. Save the changes by pressing the SELECT key, or cancel by pressing the BACK key.