CELL-DYN
3000 System Operator’s Manual
A-3
9140240E — May 1995
Appendix A Bar Codes
Interleaved 2 of 5
Interleaved 2 of 5 encodes the 10 numeric digits 0–9. The name is
derived from the method used to encode two characters which are paired
together. Bars represent the first character and the interleaved spaces
represent the second character. Each character has two wide elements
and three narrow elements, for a total of five elements.
Codabar
Codabar uses four bars and three spaces to represent the ten numeric
digits 0-9 and certain special characters. The code is characterized by
four unique start/stop codes and variable intercharacter spacing.
CELL-DYN 3000 Bar Code Specifications
The CELL-DYN 3000 Sample Loader Bar Code Reader can read Code
39, Interleaved 2 of 5 and Codabar formats. The Sample Loader can read
these formats interchangeably if the check digit is disabled by using the
[BAR CODE SETUP] soft key from the
Code size and collection tube length limit the number of characters per
label as follows:
•
Code 39 — maximum of 9 characters. Do NOT use those that
contain only a single letter or double letters (A-ZZ). These
identify sample rack positions
more details.)
•
Interleaved 2 of 5 — 10 or 12 characters only.
•
Codabar — maximum of 12 characters.
Bar Code Label Specifications
specifications:
•
Printed on good quality label stock
•
0.25 inch quiet zone on each end
•
0.01 inch minimum narrow bar width
•
2:1 wide to narrow bar ratio
•
0.5 inch minimum bar length
•
2 inch maximum label length
•
1.25 inch maximum label width
•
Maximum possible contrast between bars and background label
Search
Go Back
Book TOC
Book TOC
Содержание CELL-DYN 3000
Страница 31: ...10 CELL DYN 3000 System Operator s Manual 9140240E May 1995 NOTES Search Go Back Book TOC ...
Страница 265: ...6 10 CELL DYN 3000 System Operator s Manual 9140240E May 1995 Calibration Chapter 6 NOTES Search Go Back Book TOC ...
Страница 287: ...6 32 CELL DYN 3000 System Operator s Manual 9140240E May 1995 Calibration Chapter 6 NOTES Search Go Back Book TOC ...
Страница 313: ...6 58 CELL DYN 3000 System Operator s Manual 9140240E May 1995 Calibration Chapter 6 NOTES Search Go Back Book TOC ...
Страница 347: ...6 92 CELL DYN 3000 System Operator s Manual 9140240E May 1995 Calibration Chapter 6 NOTES Search Go Back Book TOC ...
Страница 351: ...7 2 CELL DYN 3000 System Operator s Manual 9140240E May 1995 Quality Control Chapter 7 NOTES Search Go Back Book TOC ...
Страница 369: ...7 20 CELL DYN 3000 System Operator s Manual 9140240E May 1995 Quality Control Chapter 7 NOTES Search Go Back Book TOC ...
Страница 371: ...7 22 CELL DYN 3000 System Operator s Manual 9140240E May 1995 Quality Control Chapter 7 NOTES Search Go Back Book TOC ...
Страница 387: ...9 6 CELL DYN 3000 System Operator s Manual 9140240E May 1995 Maintenance Chapter 9 NOTES Search Go Back Book TOC ...
Страница 405: ...9 24 CELL DYN 3000 System Operator s Manual 9140240E May 1995 Maintenance Chapter 9 NOTES Search Go Back Book TOC ...
Страница 431: ...10 2 CELL DYN 3000 System Operator s Manual 9140240E May 1995 Troubleshooting Chapter 10 NOTES Search Go Back Book TOC ...
Страница 473: ...10 44 CELL DYN 3000 System Operator s Manual 9140240E May 1995 Troubleshooting Chapter 10 NOTES Search Go Back Book TOC ...
Страница 495: ...10 66 CELL DYN 3000 System Operator s Manual 9140240E May 1995 Troubleshooting Chapter 10 NOTES Search Go Back Book TOC ...
Страница 509: ...10 80 CELL DYN 3000 System Operator s Manual 9140240E May 1995 Troubleshooting Chapter 10 NOTES Search Go Back Book TOC ...
Страница 535: ...12 16 CELL DYN 3000 System Operator s Manual 9140240E May 1995 Sample Loader Chapter 12 NOTES Search Go Back Book TOC ...