Chapter 88 Networked AV Mode
XS3800-28 User’s Guide
737
The following table describes the labels in this screen.
88.34 SECURITY
The following sections introduce the
SECURITY
screens.
88.35 Access Control
A console port and FTP are allowed one session each, Telnet and SSH share nine sessions, up to five Web
sessions (five different user names and passwords) and/or limitless SNMP access control sessions are
allowed.
Table 400 SWITCHING > VLAN > VLAN Port Setup
LABEL
DESCRIPTION
Port
This field displays the port number.
*
Settings in this row apply to all ports.
Use this row only if you want to make some settings the same for all ports. Use this row first to set
the common settings and then make adjustments on a port-by-port basis.
Note: Changes in this row are copied to all the ports as soon as you make them.
Ingress Check
If this check box is selected, the Switch discards incoming frames on a port for VLANs that do
not include this port in its member set.
Clear this check box to disable ingress filtering.
PVID
A PVID (Port VLAN ID) is a tag that adds to incoming untagged frames received on a port so
that the frames are forwarded to the VLAN group that the tag defines.
Enter a number between 1and 4094 as the port VLAN ID.
Acceptable
Frame Type
Specify the type of frames allowed on a port. Choices are
All
,
Tag Only
and
Untag Only
.
Select
All
from the drop-down list box to accept all untagged or tagged frames on this port.
This is the default setting.
Select
Tag Only
to accept only tagged frames on this port. All untagged frames will be
dropped.
Select
Untag Only
to accept only untagged frames on this port. All tagged frames will be
dropped.
VLAN Trunking
Enable
VLAN Trunking
on ports connected to other switches or routers (but not ports directly
connected to end users) to allow frames belonging to unknown VLAN groups to pass through
the Switch.
Isolation
Select this to allows this port to communicate only with the CPU management port and the
ports on which the isolation feature is NOT enabled.
Apply
Click
Apply
to save your changes to the Switch’s run-time memory. The Switch loses these
changes if it is turned off or loses power, so use the
Save
link on the top navigation panel to
save your changes to the non-volatile memory when you are done configuring.
Cancel
Click
Cancel
to begin configuring this screen afresh.
Table 401 Access Control Overview
Console Port
SSH
Telnet
FTP
Web
SNMP
One session
Share up to 9 sessions
One session
Up to 5 accounts
No limit
Summary of Contents for XS3800-28
Page 29: ...29 PART I User s Guide...
Page 54: ...54 PART II Technical Reference...
Page 88: ...Chapter 4 Web Configurator XS3800 28 User s Guide 88 Figure 51 Online Web Help...
Page 148: ...Chapter 20 Cloud Management XS3800 28 User s Guide 148 Figure 94 SYSTEM Cloud Management...
Page 263: ...Chapter 36 OAM XS3800 28 User s Guide 263 Figure 182 PORT OAM OAM Status OAM Details...
Page 540: ...Chapter 72 VRRP XS3800 28 User s Guide 540 Figure 434 VRRP Example 2 VRRP Status on Switch B...
Page 581: ...Chapter 77 Policy Rule XS3800 28 User s Guide 581 Figure 456 Policy Example...