Chapter 38 ZULD
XS3800-28 User’s Guide
274
devices too. If OAM is not enabled initially,
ZULD
will not work.
• If OAM is enabled initially and later disabled on one end of a link, the link will be unidirectional as that
end cannot send OAMPDUs.
• OAM discovery, the sending of OAMPDUs to other ports, is initiated by an active port.
• When
ZULD
detects a unidirectional link, it sends a syslog and SNMP trap and may shut down the
affected port (
Aggressive Mode
).
• If a port on the Switch is shut down by
ZULD
, and you want to recover it, then do one of the following:
• Go to
PORT
>
Port Setup
. Clear
Active
and click
Apply
. Then select
Active
and click
Apply
again.
• Go to
SECURITY
>
Errdisable
>
Errdisable Recovery
and set the interval for
ZULD
. After the interval
expires, the closed ports will become active and start receiving packets again.
• Use the command
port no inactive
.
• Refer to the ZULD logs to see when a unidirectional link is detected and when it is recovered to a
bidirectional link.
38.2 ZULD Status
Use this screen to see details of unidirectional and bidirectional links discovered by
ZULD
. To open this
screen, click
PORT
>
ZULD
>
ZULD Status
.
Figure 190
PORT > ZULD > ZULD Status (Standalone Mode)
Summary of Contents for XS3800-28
Page 29: ...29 PART I User s Guide...
Page 54: ...54 PART II Technical Reference...
Page 88: ...Chapter 4 Web Configurator XS3800 28 User s Guide 88 Figure 51 Online Web Help...
Page 148: ...Chapter 20 Cloud Management XS3800 28 User s Guide 148 Figure 94 SYSTEM Cloud Management...
Page 263: ...Chapter 36 OAM XS3800 28 User s Guide 263 Figure 182 PORT OAM OAM Status OAM Details...
Page 540: ...Chapter 72 VRRP XS3800 28 User s Guide 540 Figure 434 VRRP Example 2 VRRP Status on Switch B...
Page 581: ...Chapter 77 Policy Rule XS3800 28 User s Guide 581 Figure 456 Policy Example...