Chapter 72 VRRP
XS3800-28 User’s Guide
538
Figure 429
VRRP Example 1: VRRP Status on Switch B
72.4.2 Two Subnets Example
The following figure depicts an example in which two switches share the network traffic. Hosts in the two
network groups use different default gateways. Each switch is configured to backup a virtual router
using VRRP.
You wish to configure switch
A
as the master router for virtual router
VR1
and as a backup for virtual
router
VR2
. On the other hand, switch
B
is the master for
VR2
and a backup for
VR1
.
Figure 430
VRRP Configuration Example: Two Virtual Router Network
You need to configure the
VRRP Configuration
screen for virtual router VR2 on each switch, while
keeping the VRRP configuration in example 1 for virtual router
VR1
(refer to
Configure the VRRP parameters on the switches as shown in the figures below.