Chapter 53 sFlow
XS3800-28 User’s Guide
373
The following table describes the labels in this screen.
53.3 sFlow Collector Configuration
Click
SWITHCING
>
sFlow
>
Collector
to display the screen as shown. You may want to configure more
than one collector if the traffic load to be monitored is more than one collector can manage.
Note: You can configure up to four sFlow collectors in this screen.
Figure 278
SWITHCING > sFlow > Collector
Table 177 SWITCHING > sFlow
LABEL
DESCRIPTION
Active
Enable the switch button to enable the sFlow agent on the Switch.
SLOT
This field appears only in Stacking mode. Click the drop-down list to choose the slot number of
the Switch in a stack.
Port
This field displays the port number. In Stacking mode, the first number represents the slot ID and
the second is the port number. Please note that the default stacking ports (the last four ports of
your Switch) cannot be configured. They are reserved for stacking only.
*
Settings in this row apply to all ports.
Use this row only if you want to make some settings the same for all ports. Use this row first to set
the common settings and then make adjustments on a port-by-port basis.
Note: Changes in this row are copied to all the ports as soon as you make them.
Active
Select this to allow the Switch to monitor traffic on this port and generate and send sFlow
datagram to the specified collector.
Sample-rate
Enter a number (N) from 256 to 65535. The Switch captures every one out of N packets for this
port and creates sFlow datagram.
Poll-interval
Specify a time interval (from 20 to 120 in seconds) the Switch waits before sending the sFlow
datagram and packet counters for this port to the collector.
Collector
Address
Enter the IP address of the sFlow collector.
Note: You must have the sFlow collector already configured in the
SWITCHING
>
sFlow
>
Collector
screen. The sFlow collector does not need to be in the same subnet
as the Switch, but it must be accessible from the Switch.
Note: Configure UDP port 6343 (the default) on a NAT router to allow port forwarding
if the collector is behind a NAT router. Configure a firewall rule for UDP port 6343
(the default) to allow incoming traffic if the collector is behind a firewall.
Apply
Click
Apply
to save your changes to the Switch’s run-time memory. The Switch loses these
changes if it is turned off or loses power, so use the
Save
link on the top navigation panel to save
your changes to the non-volatile memory when you are done configuring.
Cancel
Click
Cancel
to begin configuring this screen afresh.
Summary of Contents for XS3800-28
Page 29: ...29 PART I User s Guide...
Page 54: ...54 PART II Technical Reference...
Page 88: ...Chapter 4 Web Configurator XS3800 28 User s Guide 88 Figure 51 Online Web Help...
Page 148: ...Chapter 20 Cloud Management XS3800 28 User s Guide 148 Figure 94 SYSTEM Cloud Management...
Page 263: ...Chapter 36 OAM XS3800 28 User s Guide 263 Figure 182 PORT OAM OAM Status OAM Details...
Page 540: ...Chapter 72 VRRP XS3800 28 User s Guide 540 Figure 434 VRRP Example 2 VRRP Status on Switch B...
Page 581: ...Chapter 77 Policy Rule XS3800 28 User s Guide 581 Figure 456 Policy Example...