2-10
GY-2120WD/WS
Adjustment
(1) Activate the terminal software.
(2) Enter the drive maintenance (MDRV) mode.
Refer to Section 6-2-6.
(3) Enter “RF05: REC Current Adjust”.
(4) Insert a blank tape.
(5) Press the “Y” key to initiate the adjustment.
(6) When the adjustment succeeds, message
“Adjust Complete” is displayed on the
screen.
n
The data values described on right are
samples.
(7) Enter “RF07: RF NV-RAM Save”.
(8) Press the “Y” key to save the adjustment data
in a NV-RAM.
(9) When the data saving is completed, message
“Saving....OK” is displayed on the screen.
2-2. Periodic check
------>RF05
RF Adjust [Auto Adjust]
REC Current Adjust
Set Blank Tape
Are you ready (y/n/else=Eject)? Yes
Adjust Complete
Ach REC Current 80
Bch REC Current 80
Cch REC Current 80
Dch REC Current 80
------>_
RF Adjust [NV-RAM Control]
RF NV-RAM Save
Are you ready (y/n)? Yes
Saving....OK
Data Saved
------>_