![Sony GY-2120WD Maintenance Manual Download Page 366](http://html.mh-extra.com/html/sony/gy-2120wd/gy-2120wd_maintenance-manual_410991366.webp)
6-142
GY-2120WD/WS
>>>>>>>>>>>>>>>>>>>>>>>>>>[ 2-PORT COMMAND LOG ]<<<<<<<<<<<<<<<<<<<<<<<<<<<
<<<< Log Count : 128 >>>>
No..TIME......STATUS..CMD..INFORMATION.......................................BOOT
89 04E7DA86 [RCV 7] 03 ID [ 16617] len [ 0] eod [ 0] rty [ 0] 00062
ERROR!! parm[00000000:00000000:00000000] err[00000124]
111 04E86107 [RCV 0] 02 ID [ 1720] len [ 280] eod [ 0] rty [ 0] 00062
parm[00000000:00000000:00000000]
113 04E86300 [RCV 1] 02 ID [ 2000] len [ 500] eod [ 0] rty [ 0] 00062
parm[00000000:00000000:00000000]
119 04E86428 [RCV 1] 19 ID [ 2252] len [ 252] eod [ 0] rty [ 0] 00062
parm[00000000:00000000:00000000]
len[ 280]
+
len[ 500]
+
len[ 252] = 1032ID > 767ID
Therefore, the Syscom Time Code Log when ERROR!! occurred does not remain.
Syscon Time Code Logger Display
Logger mem pointer : Log No. : Sys ID R/W Len R6 TCR TCR UB
PB_ENV_LEVEL
log_rp = 0000DA80 : No = 0000 : 00000743 00FF0012 28 00003029 00000000
ID
log_rp = 0000DA90 : No = 0001 : 00003026 0600001F 00 75747672 046F0902
log_rp = 0000DAA0 : No = 0002 : 010A0A0A 070F0010 00 00000001 00000000
Correction ability
log_rp = 0000DAB0 : No = 0003 : FF0A0A0A D0D0D000 00 F8FCFCD0 B2FFFFF9
C,B,A
D
ID:
0x00000743 = ID 1859
Correction ability:Writing 0A0A0A
(Write is 0A0A0A, read is 1A1A1A)
The Confi. Head state can be known during write.
C1 is the number of normally corrected blocks (total 208)
A : Ach. 0xD0 = 208
B : Bch. 0xD0 = 208
C : Cch. 0xD0 = 208
D : Cch. 0xD0 = 208
C1 means that all channels are normal.
6-3. Error Processing
↓
↑
↑
↑
↑
↑
↑