![Sony GY-2120WD Maintenance Manual Download Page 32](http://html.mh-extra.com/html/sony/gy-2120wd/gy-2120wd_maintenance-manual_410991032.webp)
1-22
GY-2120WD/WS
1-7. Power Block
1-7-5. Voltage and Power Requirements
w
Be sure to operate the unit within the range of recommend-
ed power voltage.
Recommended power voltage:
AC 100 to 240 V
±
10%
Recommended power frequency: 50 Hz or 60 Hz
Power consumption: 200VA (at 100V)
192VA (at 240V)
Rush current:
Power voltage 100 V IN; 15 A
Power voltage 240 V IN; 30 A
This unit’s power line has a switching regulator with the
power efficiencies 98%.
n
AC power supply is required a capacity which is commen-
surate with rush current.
If the capacity of the AC power supply is not enough, the
breaker of AC power of a supply side may operate or this
unit may not operate normaly.
1-7-6. Power Cord
w
To avoid a fire or an electric shock, use the specified
power cord only when connecting.
Never use a injured power cord.
Power cord for the customer in the U.S.A. and Canada.
1
DK-2401(UC) (approx. 2.4 m)
2
Plug holder (Black)
2-990-242-01
Plug holder is included in DK-2401(UC).
Power cord for the customer in the United Kingdom.
1
DK-2401(UK) (approx. 2.4 m)
2
Plug holder (Black)
2-990-242-01
Plug holder is included in DK-2401(UK).
Power cord for the customer in Europe except the United
Kingdom.
1
DK-2401(AE) (approx. 2.4 m)
2
Plug holder (Black)
2-990-242-01
Plug holder is included in DK-2401(AE).
If the unit is used in the area except above, please consult
with local Sony's sales/service office.
AC inlet
2
1
2
AC inlet
1
AC inlet
2
1
Summary of Contents for GY-2120WD
Page 10: ......
Page 224: ......
Page 437: ...7 3 GY 2120WD WS Index Mechanical Deck Overall Block 6 7 9 8 2 1 3 4 5 ...
Page 469: ...8 1 GY 2120WD WS 8 1 Section 8 Block Diagrams Frame Wiring ...
Page 476: ......
Page 482: ......