6-169
GY-2120WD/WS
2x 13
(ERROR 13)
Tape end sensor defective
Description:
Malfuncion of tape end sensor was detected.
Detection conditions:
When the tape end is detected continuously for more than eight seconds
Subcode:
None (Displays 00.)
Possible cause:
.
Tape end sensor trouble
.
Tape end detection circuit (DR-327 board or MS-54 board) trouble
.
Tape end input port (MA-83 board) trouble
.
Harness disconnection
.
The tape cannot move at the tape end due to troubles other than the tape sensor.
Protection operation:
In the REW mode, continues the operation until the tape top is detected. Stops the tape
transport and enters the rest state when the tape top is detected.
During the tape transport in reverse direction, the REW mode can be entered only while the
total tape quantity is observed.
Stops the tape transport and enters the rest state during tape transport except the above.
2x 14
(ERROR 14)
Cooling fan defective
Description:
Malfunction of cooling fan motor was detected.
Detection conditions:
When the fan motor FG frequency is less than the specified value continuously for more
than one second. Otherwise, the thermal sensor on EQ-66 board is detected that the temper-
ature in unit is more than the specified value.
Subcode:
None (Displays 00.)
Possible cause:
.
Fan motor trouble
.
Fan motor rotation detection circuit (MA-83 board) trouble
.
Thermal sensor (TH601 on the EQ-66 board) trouble
Protection operation:
None