![Sony GY-2120WD Maintenance Manual Download Page 41](http://html.mh-extra.com/html/sony/gy-2120wd/gy-2120wd_maintenance-manual_410991041.webp)
1-31
GY-2120WD/WS
RS-232C Port
RS-232C
GY-2120WD/
PC
*
1
2120WS
1-10. GY-2120 Control Software remo. exe
1-10. GY-2120 Control Software remo. exe
This software is used to perform the tape recording,
playback, rewinding, fast-forward, and stop operations and
cassette eject operation during adjustment of GY-
2120WD/2120WS using an IBM PC/AT(note 1)-compati-
ble machine (referred to as a PC hereafter).
1-10-1. Connection
*
1: For the RS-232C cable that connects the GY-
2120WD/2120WS and PC, refer to Section 1-4.
1-10-2. RS-232C Setting
1.
Activate the terminal software using a PC.
Communication baud rate: 9600 bps
Character length:
8 bits
Stop bit:
1
Parity:
None
2.
Set setup switch 8 on the rear panel of the GY-
2120WD/2120WS to OFF, then turn on the power of
the GY-2120WD/2120WS.
3.
Operate from the PC as described below.
SERV(ENTER)
←
Enter “SERV” from the PC.
SERV=>21(ENTER)
←
Enter menu No. 21.
Serial Baud Rate (default 4)
[0: 2400 bps/1: 4800 bps/2: 9600 bps/3: 19,200 bps/4:
38,400 bps] = 4
←
Current setting
BAUD RATE=>0(ENTER)
←
To set 2400 bps,
enter “0”,
SERV=>quit(ENTER)
←
To terminate the system,
enter “quit”.
Exit SERVICE SET MODE
n
After “0” is entered for the “BAUD RATE=>” prompt, do not
turn off the power until the “SERV=>” prompt is displayed.
4.
Turn off the power of the GY-2120WD/2120WS.
5.
Terminate the terminal software of the PC.
(Note 1) IBM PC AT is a registered trademark of IBM corporation
.
1-10-3. Activation and Screen Display
1.
Enter “remo” from the keyboard of a PC to activate the
remo.exe software.
2.
Set setup switch 8 on the rear panel of the GY-
2120WD/2120WS to ON, then turn on the power of
the GY-2120WD/2120WS.
3.
The screnn below is displayed after approximately 30
seconds.
Operation display
*
1 mode: Displays the IDR/IDC and read values.
*
2 TAPE: Displays the winding state of the tape.
Beginning of tape
→
BOT
Intermediate position
→
No display
End of tape
→
EOT
*
3:
Displays the entry from the keyboard.
Remote Controller
mode IDR
*
1
*
2
*
3
TAPE
FFWD
F1
F2
F3
F4
F5
F6
F7
F9
F10
FWD
RWD
SERCH
MARK
ESC
EJECT
REC
Stby
STOP