![Sony GY-2120WD Maintenance Manual Download Page 211](http://html.mh-extra.com/html/sony/gy-2120wd/gy-2120wd_maintenance-manual_410991211.webp)
5-25
GY-2120WD/WS
5-6. CTL/TC Head Azimuth Adjustment
Note
The CTL/TC head azimuth adjustment is closely related to the head position adjust-
ment and head height adjustment.
Be sure to perform adjustments (or checks) according to “In case the adjustment is
performed” in this section when the CTL/TC head azimuth is adjusted.
Equipment
.
Oscilloscope
.
PC (IBM PC/AT compatible machine)
*
For connection of a PC, refer to Section 5-1.
Tools
.
Alignment tape YR2-1: 8-960-074-11
.
GY-2120 control software (remo.exe)
Preparation
1. Turn the Power Off
2. Connect the Oscilloscope
CH-1: TP710/EQ-66 board (CTL PLS signal)
CH-2: TP705/EQ-66board (RSYC signal)
3. Set the Alignment Tape
Set the YR2-1 and put a weight (about 1000 g)
on the cassette so that it does not rise up.
5-6. CTL/TC Head Azimuth Adjustment
Preparation
*
Connection of the oscilloscope
CH-1 : TP710/EQ-66 board (CTL PLS signal)
CH-2 : TP705/EQ-66 board (RSYC signal)
<EQ-66 board, side A>
TP708
1
E701
TP706
TP709
TP705
TP703
TP710
TP602
TP601
E201
TP203
TP202
TP600
TP102
TP100
TP103
TP402
TP302
TP400
TP300
TP204
E400
TP404
TP401
TP304
TP301
E300
TP503
E500
2
3
4
5
6
7
TP101
E600
TP201 TP200
TP701
TP700
TP702
A
B
CD
E
E700
TP104
E200
E101
8
9
TP504
TP704
TP305
TP405
TP705
TP710