6-117
GY-2120WD/WS
In case of NG:
When the reel table operation is defective:
.
Confirm that there is no mechanical abnormality.
.
Check the reel shift motor drive circuit (DR-327 board or MS-54 board).
.
Check the reel shift motor.
When the reel table is in the S position and L position but message “........” is displayed:
.
Check the S position sensor and L position sensor (PTC-71 board).
.
Check the sensor input port of a CPU (MS-54 board).
6-2. Description of Commands
< Upper-side view >
S position sensor
(S position state)
Reel shift motior
T reel table
L position sensor
S reel table