![Sony GY-2120WD Maintenance Manual Download Page 338](http://html.mh-extra.com/html/sony/gy-2120wd/gy-2120wd_maintenance-manual_410991338.webp)
6-114
GY-2120WD/WS
SV15
Capstan Motor Check (Servo check command)
Function
: Checks the function of a capstan motor automatically.
Operation
: (1) Enter command.
*
A cassette tape is automatically ejected when it has been inserted into this unit in this case. A check is then
initiated.
(2) Confirm that message “Forward...OK” is displayed on the screen.
Moreover, confirm that message “Reverse...OK” is displayed.
*
The “Forward” and “Reverse” check is repeatedly executed until the CTRL and C keys are pressed simulta-
neously.
If “NG” is frequently displayed, refer to In Case of NG on this page.
*
The types of the “NG” display are as follows:
NG(speed)
: Indicates that the speed is under the prescribed speed.
NG(direction) : Indicates that the rotation direction does not coincide.
(3) To terminate a check, press the CTRL and C keys simultaneously.
*
The capstan motor automatically stops when the CTRL and C keys are pressed simultaneously.
Example:
------>sv15
Servo Check [Motor Check]
Capstan Motor Check
[KEY] CTRL-C=EXIT
Auto Check Start
Forward...OK
Reverse...OK
Forward...OK
Reverse...OK
Forward...OK
Exiting...
------>_
In case of NG:
.
Check the capstan motor drive circuit (DR-327 board or MS-54 board).
.
Confirm the capstan FG output.
.
Check the capstan motor FG amplifier circuit (DR-327 board).