h) Continuous Setting (Service setting command No. 2)
Enter “2” as a command and press the ENTER key.
Set the command numbers 21, 23 and 24 continuously.
SERV => 2
Serial Baud Rate (default 4)
[0:2400bps/1:4800bps/2:9600bps/3:19200bps/4:38400bps] = 4
BAUD RATE => 1
Ignore Wide Residue Message Mode (default Report-ON) = Report-ON
[0:OFF/other(digit):ON] => 1
BT Bit Ignore Mode (default OFF) = Check [OFF]
[0:OFF/other(digit):ON] => 1
Report Early Warning (default OFF) = REW [OFF]
[0:OFF/other(digit):ON] => 1
PetaServo Mode (default OFF) = OFF
[0:OFF/other(digit):ON] => 1
A-A Mode (default OFF) = OFF
[0:OFF/other(digit):ON] => 1
COMP SW Mode (default OFF) = OFF
[0:OFF/other(digit):ON] => 1
SERV =>