6-78
GY-2120WD/WS
6-2. Description of Commands
!;
: normal_ltc_count (Hex, Frame)
Number of frames at which the LTC could be normally read while executing longitudinal search
CMD.
If LTC could be read normally, it is determined that RD06 is x8 (Hex).
When 1_search_count becomes 51 (=33 Hex frame), if counted more than 41 (=29 Hex) frames,
it is determined that the LTC of this block was recorded normally.
Normal value
Above (1_search_count-10)
!'
to
@/
: CTL (BCD, Time Code)
Relative Time Code value counted using CTL
gg : hours
hh : minutes
ii : seconds
jj : Frames
@-
: normal_ctl_count (Hex, Frame)
Relative Time Code value counted using CTL
Number of frames counted by the CTL while executing longitudinal search CMD.
When 1_search_count becomes 51 (=33 Hex) frame, if counted more than 41 (=29 Hex) frames,
it is determined that the CTL of this block was recorded normally.
Normal value Above (1_search_count-10)
@=
: total_search_count (Hex, Frame)
Total number of frames when counting with IDC (C_CTL_COUNT) while executing longitudi-
nal search CMD
Summary of Contents for GY-2120WD
Page 10: ......
Page 224: ......
Page 437: ...7 3 GY 2120WD WS Index Mechanical Deck Overall Block 6 7 9 8 2 1 3 4 5 ...
Page 469: ...8 1 GY 2120WD WS 8 1 Section 8 Block Diagrams Frame Wiring ...
Page 476: ......
Page 482: ......